Turn a room into a controlled hygienic clinical environment.
ASEPTIZER reduces the particle and bioaerosol load through H14 HEPA filtration, UVION Atmospheric Plasma, and active air management.
Creates positive and negative pressure hygienic clinical environments. Thanks to its compact structure, it provides fast installation, low energy consumption, and high-performance safe air management.
No construction required for installation!
UVION ATMOSPHERIC PLASMA
ACTIVE DECONTAMINATION
With Atmospheric Plasma and ion technology, it breaks down bioaerosols, rendering viruses, bacteria, fungi, spores, etc. inactive.
PARTICLE AND BIO DECONTAMINATION PERFORMANCE
Hygienic Ambient Air Decontamination and Pressure Management Platform
1200 - 2500 m3/h
Total Air Capacity
H14 HEPA FILTRATION
EN 1822 Standard
10-20 THEORETICAL ACH
Depending on Model and Room Volume
POSITIVE / NEGATIVE PRESSURE
Isolation and Protection Applications
HOSPITAL, ISOLATION AND CLEAN ROOM / AIR CONDITIONING
Three-in-One Clinical Air Management
By combining filtration, pressure control, and air conditioning in a single system, it delivers fast, flexible, reliable, and hygienic solutions.
ISOLATION (Negative Pressure)
Isolates the source of infection and prevents its spread.
- Emergency department isolation rooms
- Intensive care isolation rooms
- Tuberculosis rooms
- Respiratory tract infection rooms
- Bronchoscopy and aerosol procedures
- Areas with suspected infection
GOAL:
Inward-to-outward airflow / Preventing spread. Fast commissioning
FLEX (Negative / Positive Pressure) Flexible Use
Used for hybrid purposes in places requiring both positive and negative use in the same area.
- Intensive care and recovery areas
- Operating rooms
- Isolation Rooms
- Container and field hospitals
- Clean rooms, Chemical areas
- Clinical areas
GOAL:
Multi-purpose use in creating bidirectional, negative and positive pressure environments. Fast commissioning
PROTECTION (Positive Pressure)
Provides a safe environment in sensitive and large areas.
- Operating rooms
- Intensive care rooms
- Immunosuppressed patient rooms
- Neonatal units
- Clean rooms and laboratories
- Container and field hospitals
- Pharmaceutical and medical production areas
GOAL:
Positive pressure is created in the protected area relative to surrounding volumes. By directing the airflow from the protected area outward, the ingress of external contamination is limited. Fast commissioning
Room and design data
You may enter decimal values with a dot or comma.
Aseptizer Product Family
| Air Flow Rate | 1,200 m³/h |
| Effective Volume (Class 10,000) |
80 m³ |
| Effective Volume (Class 100,000) |
110 m³ |
| Theoretical ACH | 12 - 25 |
| Pressure Mode (Pa) | Negative |
| Dimensions (cm) | 78 × 56 × 225 |
| Weight | 147 kg |
| Final Filter | H14 |
| Air Conditioning Capacity | 10,000 BTU/h |
| Fresh Air or Exhaust | 600 m³/h |
| Sound Level | 55 dB@1 m |
Aseptizer CW650 IO
CW650 IO DataSheet
*Values are taken for approximately h 3m.
| Air Flow Rate | 2,000 m³/h |
| Effective Volume (Class 10,000) |
110 m³ |
| Effective Volume (Class 100,000) |
150 m³ |
| Theoretical ACH | 10 – 20 |
| Pressure Mode (Pa) | Positive / Negative |
| Dimensions (cm) | 108.5 × 56 × 225 |
| Weight | 190 kg |
| Final Filter | H14 |
| Air Conditioning Capacity | 24,000 BTU/h |
| Fresh Air or Exhaust | 600 m³/h |
| Sound Level | 55 dB@1 m |
| Air Flow Rate | 2,500 m³/h |
| Effective Volume (Class 10,000) |
130 m³ |
| Effective Volume (Class 100,000) |
170 m³ |
| Theoretical ACH | 8 – 20 |
| Pressure Mode (Pa) | Positive |
| Dimensions (cm) | 139 × 56 × 225 |
| Weight | 217 kg |
| Final Filter | H14 |
| Air Conditioning Capacity | 24,000 BTU/h |
| Fresh Air or Exhaust | 700 m³/h |
| Sound Level | 55 dB@1 m |
Areas of Use
Uvion Air Aseptizer; wherever high hygiene and air conditioning are required, for example; Operating Rooms, Isolation Rooms, Intensive care areas (Neonatal, Pediatric, Adult), Patient rooms, Burn Treatment Units, Emergency Units, Dialysis Units, Blood Bank Units, Organ and Bone Marrow Transplant Services, Contamination (Tuberculosis, etc.) Laboratories, Micro technology laboratories, Nano technology laboratories, Production facilities such as electronics and microelectronics (Food, Pharmaceutical, Medical Device), Clean Rooms, Veterinary Clinics, etc.
It has been developed as an alternative to central systems in all positive and negative pressure environments. Thanks to its compact structure, it requires no construction.
Aseptizer can be used especially in environments without a central HVAC installation system, in environments where the HVAC system is insufficient, in areas where air ducting cannot be routed due to low ceiling height, in areas where an environment independent of the general central system is desired to be created on its own, in supporting existing ventilation, and in all types of areas where continuous re-processing of the ambient air or reinforcement of local air hygiene is required. It is also successfully used in hygienic air modernization of old buildings without disrupting the building architecture.
Although the Aseptizer Clinical Air Management System is also used in medicine, it is not covered by the "Medical Device Regulation."